Monitoring free lifetime monitoring via enlighten software compliance ul1741ieee1547, fcc part 15 class b, cancsac22. Enphase microinverters the enphase m215 is a basic building block for any 208240v system, while the enphase m250 is optimized for 60 and 72cell modules of 210 310w systems. This inverter is the result of enphases desire to enhance integration with a new generation of dedicated application specific integrated circuit asic in its topology. Simply enter the coupon code below into the apply coupon field in your shopping cart to receive our special discounted price. The body of the enphase microinverter is the heat sink. I think the enphase api is underused and undersold emphase describe themselves as a software company but thats probably because there is no killer app for it yet.
These forwardlooking statements are based on enphases current expectations and. Enphase, the worlds largest producer of microinverters, plans to beat conventional inverters on. Csa see the csa certification for enphase s230 and s280 microinverters see the csa certification for enphase s230 and s280 microinverters. Enphase s280 troubleshooting solar panels solar panels. An enphase team member may follow up with you about your feedback.
The advanced, gridready microinverter is built on fifth generation enphase platform and gets the highest efficiency module level power as well as pricewatt reduction. Enphase microinverters are proven to produce more at dawn, dusk and in low light conditions. Company 2 costs more than company 1, but the apr % is lower so the overall cost of both systems is extremely close once you consider the the % apr and add it up over time. Under normal operating conditions, the temperature is 20c above ambient, but under extreme. Enphase energy continues to offer its enlighten monitoring service free for the lifetime of your solar system allowing the customer to get the absolute most out of their system. Warranty, enphase will, at its option, either 1 repair or replace the product free of charge, or 2 issue a credit or refund for the product to the owner of the system in an amount up to its actual value at the time the owner notifies enphase of the defect, as determined by enphase. Their quotes in terms of system size are nearly identical about 12,000 kwh per year. The enphase s280 microinverter was designed for highpowered, 60cell modules, compatible up to 365w solar panels. Refer to the enphase s280 microinverter installation and operation manual for details. Installation and operation manual dec 2016 1432, rev 01b enphase m250 and m215 microinverters. The enphase s280 integrates seamlessly with the enphase envoys communications gateway, and enphase enlighten monitoring and analysis software. Thirdparty studies have shown that enphase microinverters produce more energy than the leading string and dcoptimized string inverters. Enphase s280 microinverter solaren power philippines.
Enphase microinverters enphase s280 platt electric supply. Enphase m250 for 72 cell modules inverter wholesale solar. I am not sure if this is a good combination, my concern is that the enphase inverter could cutoff at 280 w and may not be able to use the panels 315w max. The enphase envoy communications systems parts sold separately also enable stateofthe art monitoring and reporting of any issues or defects. Calculating ac line voltage drop for s280 microinverters. The enphase s280 s28060ll2us microinverter is rated at 270 vac continuous ac power with peak ac output power at 280vac and is compatible with 60cell solar panels up to 360 watts stc.
Youll be able to remotely see which panel is not producing and troubleshoot your system much easier. Used with a stepup transformer, the c250 microinverter system meets the needs of large commercial installations where power distribution is. Enphase will, at its option, use new andor reconditioned parts in repairing or replacing the defective product. Installation and operation manual 1428, rev 01 enphase sseries microinverter s230s280.
Enphase s280 microinverter data input data dc s280 60ll2us, s280 60ll5us commonly used module pairings 1 235 w 365 w maximum input dc voltage 48 v peak power tracking voltage 27 v 37 v operating range 16 v 48 v minmax start voltage 22 v 48 v max dc short circuit current 15 a. Enphase sseries microinverter and engage cable safety. Enphase energy is a nasdaqlisted energy technology company headquartered in fremont, california. Enphase microinverters allow panels to operate independently, increasing. Enphase shares surged wednesday after the oncetroubled microinverter maker solidified its return to profitability despite fierce competition from archrival solaredge. The s280s all ac approach makes design and installation more simple for. S280 microinverter, 280w, 240208vac, 60hz, 1645vdc for 60 cell modules, mc comparable locking connector in, 16 engage cable out, with integrated ground designed for highpowered, 60cell modules, the advanced gridready enphase s28060ll2us microinverter is built on the fifthgeneration platform and achieves the highest efficiency for. The enphase m250 microinverter offers industryleading efficiency 96. To reduce the risk of electrical shock, and to ensure the safe installation and operation of the enphase microinverter system, follow these instructions.
Installation and operation manual 1428, rev 02 enphase sseries microinverter s230 s280. Enphase energy iq combiner 3 wiq envoy for iq micro inverters the new iq combiner box is a reduced size from the prior version. Connect the microinverter to the utility grid only after receiving prior approval from the electrical utility company. The enphase system includes the microinverter, the envoy communications gateway, and enlighten, enphases monitoring and analysis software. This is a top performing pv system with the highestefficiency lg solar 315 watt mono x neon 2 cello solar panels. Enphases fifthgeneration s280 microinverter is specifically designed for highpowered, 60cell modules and simplifies design and installation with its allac approach. When it comes to australian solar installations, conventional string inverters tower over the competition like a current converting colossus. During the warranty period, enphase will, at its option, repair or replace the defective product free of charge, provided that enphase through inspection establishes the existence of a defect that is covered by the limited warranty. Troubleshooting an enphase system north wholesale solar email protected fcc compliance. Enphase s280 with amphenol micro inverter wholesale solar. Enphase s280 microinverter data input data dc s28060ll2us commonly used module pairings 1 235 w 365 w maximum input dc voltage 48 v peak power tracking voltage 27 v 37 v operating range 16 v 48 v minmax start voltage 22 v 48 v max dc short circuit current 15 a.
Enphase envoy communications gateway installation and. Enphases 25year warranty is only transferable only as long as the microinverter remains installed at the originally installed end user location. The s280 was built on enphases premium 5th generation platform and improved upon. This equipment has been tested and found to comply with the limits for a. View and download enphase m250 troubleshooting manual online. Are enphase energy solar panels the best solar panels to. S280 microinverter data sheet 60 hz, line to line enphase.
There may be soon though, are attempting to build a global solar pv real time monitoring solution on the solarcoin blockchain. Enphase energy micro inverters do all of the inverting of power at the solar panel level dc power going in and ac power coming out. The maximum number of s28060ll2us microinverters in an ac branch circuit is 14 for 240 vac singlephase systems. S280 microinverter data sheet 60 hz, line to line view specifications for the s280 microinverter north america. The s280 is compatible with storage systems, including battery management systems. View and download enphase m250 quick install manual online.
Designed for highpowered, 60cell and 72cell solar modules, the advanced gridready enphase s280 microinverter is built on the fifthgeneration platform and achieves the highest efficiency for modulelevel power electronics along with. The maximum number allowed on a 240 vac branch circuit protected by a 20 a ocpd is 14 s280 microinverters. Storage is new, and many solar installers are being asked about it. Enphase s280 microinverter teardown reverse costing. Enphase energy are the worldwide market leaders in microinverters, having sold more than 6,000,000 units since 2008. Important safety information s280 60ll and s23060ll this document contains important instructions to use during installation of the enphase microinverter. But microinverters, which are tiny in both physical size and market share, are shaping up to beat string inverters on both price and reliability. Enphase designs and manufactures softwaredriven home energy solutions that span solar generation, home energy storage and webbased monitoring and control. This discount is available for a limited time with a minimum order quantity of twelve units. Enphase s280 microinverter to learn more about enphase offerings, visit enphase. Enphasemicroinverters enphase s280 wholesale solar. Download our free guide for integrating batteries in gridtied solar pv systems.
The enlighten appweb site sees the issue, but it doesnt give you any data other than production problem. M215 datasheet na pg1 060611 platt electric supply. I have 38 s280 enphase microinverters that have been running fine for about 7 weeks. My installer e2 solar, great company has replaced 7 of the micro inverters free of charge but now enphase will no longer reimburse them for the replacement costs. Before installing or using the enphase energy s28060ll2us, please read all instructions and cautionary markings in the technical description.
1285 1552 26 1523 1614 1480 87 1139 418 1631 652 335 951 1165 511 1028 1344 1592 1467 268 1171 1111 147 858 654 607 120 1382 389 363 1455 790 1273 558 212 374 694 496 552 455